ESTUN – ERC – Compact Control Cabinet P...

1.1 Nameplate 1.2 Model coding   1.3 Name of components   1.4 Overall dimensions   1.5 Specifications  

2. Installation

ESTUN – ERC – Compact Control Cabinet P...

2.1 Environmental requirementsInstall the robot system in an environment satisfying the following conditions. The ambient temperature should be at - 5 ℃and 55 ℃during operation, and -20 ℃to 85 ℃ during handling and maintenance. RH shall not above 95% RH with...

3. Wiring and Connection

ESTUN – ERC – Compact Control Cabinet P...

3.1 Precautions during wiring and connectionThe product installation, wiring, maintenance and inspection shall only be performed by professional maintenance workers who have received the necessary electrical training and understood enough electrical knowledge....

4. Debugging

ESTUN – ERC – Compact Control Cabinet P...

4.1 Use of teaching pendant 4.1.1 Connection of teaching pendantFor connection of teaching pendant and wiring, refer to "3.6 Teaching pendant wiring". 4.1.2 Edit methodModify the drive parameters by following the steps below. Step 1: The control cabinet will ...

5. Alarm Viewing and Processing

ESTUN – ERC – Compact Control Cabinet P...

5.1 Alarm viewingThe alarms occurred during robot running can be viewed through the teaching pendant or ESView.In case of an alarm, the robot will stop motion, and users need to take necessary measures to make the robot move continuously. If more than one alar...

6. Maintenance

ESTUN – ERC – Compact Control Cabinet P...

6.1 Precautions for maintenanceRead the following instructions before performing all maintenance works. Users need to have an adequate understanding on the method of safety maintenance. 6.2 Routine inspectionThe devices will be aged and its service life will ...

ESTUN – ERS – Control Cabinet Operation Manual (CE)

Instrukcja szafy sterowniczej robotów ESTUN serii ERS w wersji CE. Zawiera: zasady bezpieczeństwa, informacje o produkcie, transport i instalację, okablowanie i podłączenia, uruchomienie (debugging), rozwiązywanie problemów i konserwację. Język: angielski. Ź...

producent
ESTUN
produkt
ERS
typ-dokumentu
instrukcja-obsługi
język
EN
źródło
producent

Revision History

ESTUN – ERS – Control Cabinet Operation...

Preface

ESTUN – ERS – Control Cabinet Operation...

This manual primarily introduces safety precautions and usage methods for robots compatible with the control cabinets of Functional Safety Series.The robot is a part of the robot safety system and cannot operate independently without end effectors or periphera...

1. Safety Precautions

ESTUN – ERS – Control Cabinet Operation...

This Chapter describes the content to be observed for the safe use of the robot. Before using, be sure to read and understand the content in this Chapter.1. Before installation, operation, maintenance, and troubleshooting, it is essential to thoroughly read an...

2. Product Information

ESTUN – ERS – Control Cabinet Operation...

2.1 Information on nameplate Figure2.2 Model Description   2.2 Product Dimensions2.2.1 ERS-S Series CE Version Control Cabinet   2.2.2 ERS-M Series CE Version Control Cabinet   2.3 ERS-S Series CE Version Control Cabinet Part Name2.3.1 Description of appea...

3. Transportation & Installation

ESTUN – ERS – Control Cabinet Operation...

3.1 Handling Procedures   3.1.1 Transport the control cabinet with a craneBefore transporting the control cabinet, perform the following checks:1) Confirm the cabinet's weight and use a wire rope with a load capacity greater than the cabinet's weight for lift...

4. Wiring & Connection

ESTUN – ERS – Control Cabinet Operation...

  4.1 Precautions for cable connection LV cables shall be used to connect between control cabinet and peripheral equipment. The signal cables of the control cabinet shall be laid in a distance far away from the main power supply circuit, while the HV power ...

5. Debugging

ESTUN – ERS – Control Cabinet Operation...

5.1 Checks before power-onBefore powering on the control cabinet, please check and confirm the following items, and make necessary adjustments if needed. 5.2 Control Cabinet Power-up Procedures1) Ensure that no personnel are inside the safety fence.2) Ensure...

6. Troubleshooting

ESTUN – ERS – Control Cabinet Operation...

6.1 Alarm CheckDuring the operation of the robot, alarms that occur can be viewed using the teach pendantOnce an alarm occurs, the robot will stop its motion and the user will need to take necessary actions to resolve the issue before resuming robot operation....

7. Maintenance

ESTUN – ERS – Control Cabinet Operation...

7.1 Maintenance precautionsBefore performing maintenance, please carefully read the following content and ensure a thorough understanding of the methods for safe maintenance. 7.2 Daily inspectionTo ensure the normal functioning of the product and protect it f...

ESTUN – Functional Safety Series – Control Cabinet Operation Manual

Instrukcja szafy sterowniczej robotów ESTUN z funkcjami bezpieczeństwa funkcjonalnego (Functional Safety Series). Zawiera: zasady bezpieczeństwa, informacje o produkcie, transport i instalację, okablowanie i podłączenia, uruchomienie (debugging), rozwiązywani...

producent
ESTUN
produkt
Functional Safety
typ-dokumentu
instrukcja-obsługi
język
EN
źródło
producent

Revision History

ESTUN – Functional Safety Series – Cont...