Streszczenie: Metody bazowania (homing) napędów Copley: przegląd, legenda diagramów i opis każdej metody – ustawienie bieżącej pozycji jako bazy, następny impuls indeksu, wyłącznik krańcowy, twardy ogranicznik (hard stop), czujnik bazowy (home switch), lower/upper home – z kierunkiem ruchu i wartością zmiennej 0xc2.
EN: Homing methods: overview, legend and each method with direction of motion and 0xc2 value.

Dotyczy: serwonapędy Copley Controls z interfejsem ASCII (RS-232, sieć multi-drop CAN), program CME 2
Źródło: dokumentacja producenta (Copley Controls ASCII Interface Programmer’s Guide); tabele przepisane z obrazów na tekst – opracowanie Multiprojekt

This appendix describes the homing methods that can be chosen using the homing method

variable (0xc2) as described in Homing Mode, Contents include: 

C.1 Homing Methods Overview

There are several homing methods. Each method establishes the:

  • Home reference (limit or home switch transition or encoder index pulse)
  • Direction of motion and, where appropriate, the relationship of the index pulse to limit or home switches.

C.2 Legend to Homing Method Descriptions

As highlighted in the example below, each homing method diagram shows the starting position on a mechanical stage. The arrow line indicates direction of motion, and the circled H indicates the home position. Solid line stems on the index pulse line indicate index pulse locations. Longer dashed lines overlay these stems as a visual aid. Finally, the relevant limit switch is represented, showing the active and inactive zones and transition. 

Diagram: homing method – Legend to Homing Method Descriptions

Note that in the homing method descriptions, negative motion is leftward and positive motion is rightward. 

C.3 Homing Method Descriptions

C.3.1 Set current position as home

Direction of Motion: N/A (0xc2 = 512)

The current position is the home position.

C.3.2 Next Index

Direction of Motion: Positive (0xc2 =544)

Home is the first index pulse found in the positive direction. Direction of motion is positive. If a positive limit switch is activated before the index pulse, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Next Index › Direction of Motion: Positive (0xc2 =544)Diagram: homing method – Next Index › Direction of Motion: Positive (0xc2 =544)

Direction of Motion: Negative (0xc2 =560)

Home is the first index pulse found in negative direction. Direction of motion is negative. If a negative limit switch is activated before the index pulse, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Next Index › Direction of Motion: Negative (0xc2 =560)Diagram: homing method – Next Index › Direction of Motion: Negative (0xc2 =560)

C.3.3 Limit Switch

Direction of Motion: Positive (0xc2 =513)

Home is the transition of the positive limit switch. Initial direction of motion is positive if the positive limit switch is inactive. 

Diagram: homing method – Homing Method Descriptions › Limit Switch › Direction of Motion: Positive (0xc2 =513)Diagram: homing method – Limit Switch › Direction of Motion: Positive (0xc2 =513)

Direction of Motion: Negative (0xc2 =529)

Home is the transition of negative limit switch. Initial direction of motion is negative if the negative limit switch is inactive. 

Diagram: homing method – Homing Method Descriptions › Limit Switch › Direction of Motion: Negative (0xc2 =529)Diagram: homing method – Limit Switch › Direction of Motion: Negative (0xc2 =529)

C.3.4 Limit Switch Out to Index

Direction of Motion: Positive (0xc2 =545)

Home is the first index pulse to the negative side of the positive limit switch transition. Initial direction of motion is positive if the positive limit switch is inactive (shown here as low). 

Diagram: homing method – Homing Method Descriptions › Limit Switch Out to Index › Direction of Motion: Positive (0xc2 =545)Diagram: homing method – Limit Switch Out to Index › Direction of Motion: Positive (0xc2 =545)

Direction of Motion: Negative (0xc2 =561)

Home is the first index pulse to the positive side of the negative limit switch transition. Initial direction of motion is negative if the negative limit switch is inactive (shown here as low). 

Diagram: homing method – Homing Method Descriptions › Limit Switch Out to Index › Direction of Motion: Negative (0xc2 =561)Diagram: homing method – Limit Switch Out to Index › Direction of Motion: Negative (0xc2 =561)

C.3.5 Hardstop

Direction of Motion: Positive (0xc2 =516)

Home is the positive hard stop. Direction of motion is positive. The hard stop is reached when the amplifier outputs the homing Current Limit continuously for the amount of time specified in the Delay Time. If a positive limit switch is activated before the hard stop, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Hardstop › Direction of Motion: Positive (0xc2 =516)Diagram: homing method – Hardstop › Direction of Motion: Positive (0xc2 =516)

Direction of Motion: Negative (0xc2 =532)

Home is the negative hard stop. Direction of motion is negative. The hard stop is reached when the amplifier outputs the homing Current Limit continuously for the amount of time specified in the Delay Time. If a negative limit switch is activated before the hard stop, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Hardstop › Direction of Motion: Negative (0xc2 =532)Diagram: homing method – Hardstop › Direction of Motion: Negative (0xc2 =532)

Hardstop Methods in Stepper Mode

In Stepnet amplifiers operating in stepper mode with an encoder, the hard stop is reached when the following error is exceeded. When using hardstop methods in stepper mode, do not disable following error. 

C.3.6 Hardstop Out to Index

Direction of Motion: Positive (0xc2 =548)

Home is the first index pulse on the negative side of the positive hard stop. Initial direction of motion is positive. The hard stop is reached when the amplifier outputs the homing Current Limit continuously for the amount of time specified in the Delay Time. If a positive limit switch is activated before the hard stop, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Hardstop Out to Index › Direction of Motion: Positive (0xc2 =548)Diagram: homing method – Hardstop Out to Index › Direction of Motion: Positive (0xc2 =548)

Direction of Motion: Negative (0xc2 =564)

Home is the first index pulse on the positive side of the negative hard stop. Initial direction of motion is negative. The hard stop is reached when the amplifier outputs the homing Current Limit continuously for the amount of time specified in the Delay Time. If a negative limit switch is activated before the hard stop, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Hardstop Out to Index › Direction of Motion: Negative (0xc2 =564)Diagram: homing method – Hardstop Out to Index › Direction of Motion: Negative (0xc2 =564)

Hardstop Out to Index Methods in Stepper Mode

In Stepnet amplifiers operating in stepper mode with an encoder, the hard stop is reached when the following error is exceeded. When using hardstop methods in stepper mode, do not disable following error.

C.3.7 Home Switch

Direction of Motion: Positive (0xc2 =514)

Home is the home switch transition. Initial direction of motion is positive if the home switch is inactive. If a limit switch is activated before the home switch transition, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Home Switch › Direction of Motion: Positive (0xc2 =514)Diagram: homing method – Home Switch › Direction of Motion: Positive (0xc2 =514)

Direction of Motion: Negative (0xc2 =530)

Home is the home switch transition. Initial direction of motion is negative if the home switch is inactive. If a limit switch is activated before the home switch transition, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Home Switch › Direction of Motion: Negative (0xc2 =530)Diagram: homing method – Home Switch › Direction of Motion: Negative (0xc2 =530)

C.3.8 Home Switch Out to Index

Direction of Motion: Positive (0xc2 =546)

Home is the first index pulse to the negative side of the home switch transition. Initial direction of motion is positive if the home switch is inactive. If a limit switch is activated before the home switch transition, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Home Switch Out to Index › Direction of Motion: Positive (0xc2 =546)Diagram: homing method – Home Switch Out to Index › Direction of Motion: Positive (0xc2 =546)

Direction of Motion: Negative (0xc2 =562)

Home is the first index pulse to the positive side of the home switch transition. Initial direction of motion is negative if the home switch is inactive. If a limit switch is activated before the home switch transition, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Home Switch Out to Index › Direction of Motion: Negative (0xc2 =562)Diagram: homing method – Home Switch Out to Index › Direction of Motion: Negative (0xc2 =562)

C.3.9 Home Switch In to Index

Direction of Motion: Positive (0xc2 =610)

Home is the first index pulse to the positive side of the home switch transition. Initial direction of motion is positive if the home switch is inactive. If a limit switch is activated before the home switch transition, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Home Switch In to Index › Direction of Motion: Positive (0xc2 =610)Diagram: homing method – Home Switch In to Index › Direction of Motion: Positive (0xc2 =610)

Direction of Motion: Negative (0xc2 =626)

Home is the first index pulse to the negative side of the home switch transition. Initial direction of motion is negative if the home switch is inactive. If a limit switch is activated before the home switch transition, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Home Switch In to Index › Direction of Motion: Negative (0xc2 =626)Diagram: homing method – Home Switch In to Index › Direction of Motion: Negative (0xc2 =626)

C.3.10 Lower Home

Direction of Motion: Positive (0xc2 =771)

Home is the negative edge of a momentary home switch. Initial direction of motion is positive if the home switch is inactive. Motion will reverse if a positive limit switch is activated before the home switch; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Lower Home › Direction of Motion: Positive (0xc2 =771)Diagram: homing method – Lower Home › Direction of Motion: Positive (0xc2 =771)

Direction of Motion: Negative (0xc2 =787)

Home is the negative edge of a momentary home switch. Initial direction of motion is negative. If the initial motion leads away from the home switch, the axis reverses on encountering the negative limit switch; then, if a positive limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Lower Home › Direction of Motion: Negative (0xc2 =787)Diagram: homing method – Lower Home › Direction of Motion: Negative (0xc2 =787)

C.3.11 Upper Home

Direction of Motion: Positive (0xc2 =515)

Home is the positive edge of a momentary home switch. Initial direction of motion is positive. If the initial motion leads away from the home switch, the axis reverses on encountering the positive limit switch; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Upper Home › Direction of Motion: Positive (0xc2 =515)Diagram: homing method – Upper Home › Direction of Motion: Positive (0xc2 =515)

Direction of Motion: Negative (0xc2 =531)

Home is the positive edge of momentary home switch. Initial direction of motion is negative if the home switch is inactive. If the initial motion leads away from the home switch, the axis reverses on encountering the negative limit switch; then, if a positive limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Upper Home › Direction of Motion: Negative (0xc2 =531)Diagram: homing method – Upper Home › Direction of Motion: Negative (0xc2 =531)

C.3.12 Lower Home Outside Index

Direction of Motion: Positive (0xc2 =803)

Home is the first index pulse on the negative side of the negative edge of a momentary home switch. Initial direction of motion is positive if the home switch is inactive. If the initial motion leads away from the home switch, the axis reverses on encountering the positive limit switch; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Lower Home Outside Index › Direction of Motion: Positive (0xc2 =803)Diagram: homing method – Lower Home Outside Index › Direction of Motion: Positive (0xc2 =803)

Direction of Motion: Negative (0xc2 =819)

Home is the first index pulse on the negative side of the negative edge of a momentary home switch. Initial direction of motion is negative. If the initial motion leads away from the home switch, the axis reverses on encountering the negative limit switch; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Lower Home Outside Index › Direction of Motion: Negative (0xc2 =819)Diagram: homing method – Lower Home Outside Index › Direction of Motion: Negative (0xc2 =819)

C.3.13 Lower Home Inside Index

Direction of Motion: Positive (0xc2 =867)

Home is the first index pulse on the positive side of the negative edge of a momentary home switch. Initial direction of motion is positive if the home switch is inactive. If the initial motion leads away from the home switch, the axis reverses on encountering the positive limit switch; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Lower Home Inside Index › Direction of Motion: Positive (0xc2 =867)Diagram: homing method – Lower Home Inside Index › Direction of Motion: Positive (0xc2 =867)

Direction of Motion: Negative (0xc2 =883)

Home is the first index pulse on the positive side of the negative edge of a momentary home switch. Initial direction of motion is negative. If the initial motion leads away from the home switch, the axis reverses on encountering the negative limit switch; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Lower Home Inside Index › Direction of Motion: Negative (0xc2 =883)Diagram: homing method – Lower Home Inside Index › Direction of Motion: Negative (0xc2 =883)

C.3.14 Upper Home Outside Index

Direction of Motion: Positive (0xc2 = 547)

Home is the first index pulse on the positive side of the positive edge of a momentary home switch. Initial direction of motion is positive. If the initial motion leads away from the home switch, the axis reverses on encountering the positive limit switch; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Upper Home Outside Index › Direction of Motion: Positive (0xc2 = 547)Diagram: homing method – Upper Home Outside Index › Direction of Motion: Positive (0xc2 = 547)

Direction of Motion: Negative (0xc2 =563)

Home is the first index pulse on the positive side of the positive edge of a momentary home switch. Initial direction of motion is negative if the home switch is inactive. If the initial position is right of the home position, the axis reverses on encountering the home switch. 

Diagram: homing method – Homing Method Descriptions › Upper Home Outside Index › Direction of Motion: Negative (0xc2 =563)Diagram: homing method – Upper Home Outside Index › Direction of Motion: Negative (0xc2 =563)

C.3.15 Upper Home Inside Index

Direction of Motion: Positive (0xc2 =611)

Home is the first index pulse on the negative side of the positive edge of momentary home switch. Initial direction of motion is positive. If initial motion leads away from the home switch, the axis reverses on encountering the positive limit switch; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Upper Home Inside Index › Direction of Motion: Positive (0xc2 =611)Diagram: homing method – Upper Home Inside Index › Direction of Motion: Positive (0xc2 =611)

Direction of Motion: Negative (0xc2 =627)

Home is the first index pulse on the negative side of the positive edge of a momentary home switch. Initial direction of motion is negative if the home switch is inactive. If initial motion leads away from the home switch, the axis reverses on encountering the negative limit; then, if a negative limit switch is activated before the home switch, an error is generated. 

Diagram: homing method – Homing Method Descriptions › Upper Home Inside Index › Direction of Motion: Negative (0xc2 =627)Diagram: homing method – Upper Home Inside Index › Direction of Motion: Negative (0xc2 =627)