A CANopen network can support up to 127 nodes. Each node must have a unique and valid seven-bit address (Node ID) in the range of 1-127. (Address 0 should only be used when the amplifier is serving as a CME 2 serial port multi-drop gateway.)

If the amplifier is under DeviceNet control, see Copley DeviceNet Programmer’s Guide

Configure a CAN interface

1.
1 Verify that the CAN network has been cabled and terminated as per amplifier documents.
2

2. image.pngButton: CAN Configuration Click CAN Configuration to open the CAN Configuration screen. (If CAN is not the Position Loop Input, choose AmplifierNetworkAmplifier → Network Configuration instead.) 

image.pngScreenshot: Configure a CAN interface

(Note that options may vary based on amplifier model and configuration.) 

33. Choose network type (CAN or DeviceNet).
4

4. Choose a Bit Rate and choose any combination of address sources (Switch, Inputs, and Programmed Value). The address is the sum of the values from these sources.
5

5. For each source selected, perform the additional steps described below. 

image.pngCAN address source

SourceAdditional Steps
Use SwitchVerify the S1 switch setting. (Assigns values for Bit 0 – Bit 3 of CAN address.)
Use InputsEnter Number of Inputs. Choose an input to represent each CAN address bit.
Use Programmed ValueEnter the Programmed value.

66. Click Save & Reset to save changes to amplifier flash, close the screen, and reset the amplifier. Click Save & Close to save changes to amplifier flash without resetting.

NOTE: Address and bit rate changes take effect only after power-up or reset.

Słowa kluczowe

CAN, CANopen, DeviceNet, Node ID, adres węzła, bit rate, przełącznik adresu, multi-drop