8. Device Settings – Part 1 (Image Quality)
Streszczenie: Ustawienia ID3000 cz. 1: zalecana kolejność konfiguracji oraz jakość obrazu – ekspozycja, wzmocnienie, Gamma, polling (tryb single/multiple), źródło światła, ostrość obiektywu, samoczynne dopasowanie, Mirror X i obraz testowy.
EN: ID3000 settings part 1: configuration order and image quality – exposure, gain, Gamma, polling, light source, lens focus, self-adaptive adjustment, Mirror X and test pattern.
Dotyczy: przemysłowy czytnik kodów Hikrobot serii ID3000 (złącze M12 17-pin, Fast Ethernet, RS-232; obsługa przez klienta IDMVS)
Źródło: dokumentacja producenta (Hikrobot ID3000 Series Industrial Code Reader User Manual, V3.1.0); opisy rysunków – opracowanie Multiprojekt
You are recommended to complete device settings in following order: Device Connection → Image Settings → Algorithm Settings → I/O Control Settings → Data Processing → Communication Settings → Configuration Management.
Note: Before specific device settings, you need to set device mode as Normal. Otherwise, the device parameters may be different. Regarding device mode, refer to Device Mode Settings for details.
●
- Device Connection: It tells you how to connect the device to the client software. And you can configure and operate the device remotely via the client software only when you have connected the device to the client software. Refer to Connect Device to Client Software for details.
● - Image Settings: It tells you how to set image related parameters of the device via client software. Refer to Image Quality Settings for details.
● - Algorithm Settings: It tells you how to set the types of barcode to be read, the 1D code algorithm, the 2D code algorithm, etc. Refer to Code Algorithm Settings for details.
● - I/O Control Settings: It tells you how to set the parameters related to the control of input and output signals of device. Refer to Signal Input Settings and Signal Output Settings for details.
● - Data Processing: It tells you how to set filter rules for reading barcodes and other data processing related parameters. Refer to Code Reading Result Settings for details.
● - Communication Settings: It tells you how to select different communication protocols, and set their corresponding parameters. Refer to Communication Settings for details.
● - Configuration Management: It tells you how to set and manage the user parameters, restart device, etc. Refer to User Set Customization for details.
8.1 Image Quality Settings
This section introduces how to set image related parameters of the device via client software.
Note: For different models of the device, the specific parameters may differ, and the actual device you purchased shall prevail.
8.1.1 Set Image
You can set different image parameters like exposure time, gain, Gamma, acquisition frame rate, acquisition burst frame count in image parameters interface.
- Make sure
you have selected the device to be set in Device Connection before setting image parameters.
- For specific parameter range like exposure time, gain and acquisition frame rate, refer to the device’s specification for details.
Exposure Time
You can increase exposure time to improve image brightness.
Note: To some extent, increasing exposure time will reduce acquisition frame rate, and impact image quality.
Gain
You can increase gain to improve image brightness.
Note: To some extent, increasing gain will create more image noises, and impact image quality.
Gamma
Gamma
Gamma allows you to adjust the image contrast. It is recommended to reduce Gamma to increase brightness in dark background.
Acquisition Frame Rate
Acquisition frame rate refers to the image number that is acquired by the device per second.
Acquisition Burst Frame Count
Acquisition burst frame count refers to the outputted image number when the device is triggered once.
Polling Enable
It enables the polling function, you can select off, single or multiple mode.
Note: The parameter of polling enable will be displayed only when the trigger mode is on.
Figure 8-1 Set Image
Figure description (text version): Image parameter group with example values: Exposure Time (us) 799.00, Gain (dB) 0.00, Gamma 1.00, Acquisition Frame Rate (fps) 60.00, Acquisition Burst Frame Count 1, Polling Enable Off.
8.1.2 Set Polling
The polling function allows the device to acquire images based on the parameters you set, including exposure time, gain, Gamma, and light source. Currently, 2 types of polling modes are available, including single mode and multiple mode.
Single Mode
- Stopping the real-time acquisition is required before setting the polling function.
- After the polling is enabled, the device acquires images with its max. frame rate. Once the polling is disabled, the frame rate you set in Acquisition Frame Rate takes effect.
- The polling function, specific parameters as well as parameter values may differ by device models.
Steps1.
- Go to Image Settings → Image → Polling Enable, and select Single as Polling Enable.
2. - Select one parameter (e.g. Param1) from Polling Param.
3. - Set Polling Exposure Time, Polling Gain, and Polling Gamma according to actual demands
4. - Select Polling Light Selector according to actual demands, and enable Polling Light Enable.
Figure 8-2 Single Mode
Figure description (text version): Polling parameters in single mode: Polling Enable Single, Polling Param Param1, Polling Exposure Time 799.00, Polling Gain 0.00, Polling Gamma 1.00, Polling Light Selector Up, Polling Light Enable switched on.
Multiple Mode
Multiple ModeNote:
- The parameter of Best Polling Group Idx is used to display the polling parameter number when the device recognizes codes after enabling polling. If the polling is disabled or polling parameters are edited, it displays 1 by default.
- The rule for multiple-mode polling is that the polling is started from the polling parameter with Best Polling Group Idx, and then other polling parameters you selected are executed in turn. For example, if Param3 is the Best Polling Group Idx and Param1, Param2, Param4 and Param5 are enabled, the polling order is Param3 > Param1 > Param2 > Param4 > Param5.
Steps1.
- Go to Image Settings → Image → Polling Enable, and select Multiple as Polling Enable.
2. - Set Polling Time and Polling Period according to actual demands.
3. - Select 2 to 8 sets of parameters (e.g. Param1 and Param2) from Polling Param, and enable Polling Param Enable to let them take effect.
4. - Set Polling Exposure Time, Polling Gain, and Polling Gamma for the Polling Param you selected.
5. - Select Polling Light Selector according to actual demands, and enable Polling Light Enable.
6. - Repeat step 3 to step 5 to set other parameters from Polling Param.
Figure 8-3 Multiple Mode
Figure description (text version): Polling parameters in multiple mode: Polling Enable Multiple, Polling State 0, Polling Time 100, Polling Period 1, Best Polling Group Idx 1, Polling Param Param1, Polling Param Enable on, Polling Exposure Time 799.00, Polling Gain 0.00, Polling Gamma 1.00, Polling Light Selector Up, Polling Light Enable on.
Figure 8-4 Polling Diagram
Figure description (text version): Loop diagram of eight parameter sets (Parameter 1 … Parameter 8), each containing its own exposure time, gain, Gamma and lighting. Arrows run Parameter 1 → 2 → 3 → 4 → 5 → 6 → 7 → 8 and back to Parameter 1.
8.1.3 Set Light Source
You can select different light types, and set their related parameters in the light interface.
- Light source parameters may differ by device models.
- Make sure you have selected the device to be set in Device Connection before setting light source parameters.
You can select different light sources in Light Type.
Own Lighting
It refers to use the device's embedded light source to light during code reading.
External Lighting
It refers to the device controls the external light source by triggering output signal during code reading.
Non-Lighting
It refers to the device turns off light source during code reading.
Note: If you select Non-Lighting as Light Type, you do not need to set any parameters.
Set Own Lighting
If you select Own Lighting as Light Type, you can set the following parameters.
Aiming Light Enable
You can enable Aiming Light Enable to enable the device’s aiming light.
Note: The parameter of aiming light enable may differ by device model.
Lighting Selector
You can click lamps on the light source illustration to turn on or turn off lamps on different directions.
Note: The specific lighting selector may differ by device model. For devices with 4 groups of lamps, you can check All to turn on all lamps. For devices with 6 groups of lamps, you can click All On or All Off to turn on or turn off all lamps.
Light Mode
It has 2 light modes, including Strobe and Long. Strobe means the light flashes at a specific interval during code reading, and Long means the light is solid during code reading.
Lighting Duration
It sets the lighting duration and the unit is μs.
Lighting Delay Time
Note: This parameter is available only when you set Flash Strobe as the Light Mode.
It determines the delay time for lighting after exposure and the unit is μs.
Precharge Time
It determines how earlier the light source starts lighting before exposure and the unit is μs.
Figure 8-5 Light Parameters
Figure description (text version): Light parameter group: Aiming Light Enable switch, Lighting Selector with an illustration of the device front and its LED lamps (green = on) plus All On / All Off buttons, Light Mode Strobe, Lighting Duration (us) 2000, Lighting Delay Time (us) 0, Precharge Time (us) 380.Note: The figure above is only for reference. The specific graphic user interface may differ by device models.
Set External Lighting
If you select External Lighting as Light Type, you can set the following parameters.
Line Out Duration
The lighting duration of the external light source and the unit is μs.
Line Out Delay Time
It sets the delay time for lighting after device outputs event source, and the unit is μs.
Line Out Ahead Time
It sets how earlier the external light starts lighting before the device outputs event source information, and the unit is μs.
8.1.4 Set Lens Focus
The device supports setting lens focus via the client software. 2 ways are available to set lens focus, including auto focus and manual focus.
Note:
- The lens focus function may differ by device models.
- Setting the device mode as Test is required before setting lens focus. After completion, you can set the device mode as Normal.
- Setting the trigger mode as off is required before setting lens focus.
Auto Focus
Steps1.
- Click

in the live view window.2. - Go to Image Settings → Auto Focus, and click Execute in Focus Mode.
The device starts to adjust focus automatically.3. - Select the position parameter from Focus Position, and click Execute in Focus Position Save to save the focus position.
4. - (Optional) Select the position parameter from Focus Position, and click Execute in Focus Position Load to load saved focus position.
Figure 8-6 Auto Focus
Figure description (text version): Auto Focus group: Focus Mode (Execute), Focus Step 100, Focus Position Position 1, Adjust Focus with − / + buttons, FocusPosition Save (Execute), FocusPosition Load (Execute).
Manual Focus
1.
- Go to Image Settings → Auto Focus, and set Focus Step according to actual demands.
2. - Click − or + in Adjust Focus to adjust focus.
3. - Select the position parameter from Focus Position, and click Execute in Focus Position Save to save the focus position.
4. - (Optional) Select the position parameter from Focus Position, and click Execute in Focus Position Load to load saved focus position.
Figure 8-7 Manual Focus
Figure description (text version): The same Auto Focus group with Focus Step (100) and Adjust Focus (− / + buttons) highlighted in red for manual focusing.
8.1.5 Set Self-Adaptive Adjustment
Note: This function may differ by device models.
The function of self-adaptive adjustment can automatically adjust exposure, gain, Gamma and other parameters to have a better code reading effect.
Steps1.
- Right click the device in Device Connection, and click Feature Tree.
2. - Go to Self Adapt Adjust, and select Adjust Mode.
●- High Quality: In this mode, the client software will adjust exposure in priority with small gain and noise. The image quality is high, and this mode is applicable to the scenario for low speed conveyer belt.
● - High Speed: In this mode, the client software will adjust gain in priority with small exposure and large gain. The image quality is less high, and this mode is applicable to the scenario for high speed conveyer belt.
3.
- High Quality: In this mode, the client software will adjust exposure in priority with small gain and noise. The image quality is high, and this mode is applicable to the scenario for low speed conveyer belt.
- Select Param Source according to actual demands.
●- Default Param: It adjusts the default parameters.
● - Polling Param: It adjusts parameters configured in polling.
4.
- Default Param: It adjusts the default parameters.
- (Optional) Enable or disable Lighting Adapt during self-adaptive adjustment. If it is enabled, the client software will select the best one from all lighting options during the
selfadaptiveself-adaptive adjustment. If it is disabled, the client software will keep the lighting status before the self-adaptive adjustment.5. - (Optional) Set Gain Max or Exposure Max according to actual demands.
●- Gain Max: It is enabled in high quality mode, and it sets the max. gain during the
selfadaptiveself-adaptive adjustment.● - Exposure Max: It is enabled in high speed mode, and it sets the max. exposure during the self-adaptive adjustment.
- Gain Max: It is enabled in high quality mode, and it sets the max. gain during the
6.
Note: If the adjustment is completed, the client software displays the spent time and prompts that the adjustment succeeded. If the adjustment failed or timed out, the client software prompts adjustment failure or timeout.
Figure 8-8 Set Self-Adaptive Adjustment
Figure description (text version): SelfAdapt Adjust group: Adjust Mode High Quality, Param Source Default Param, Gain Max 10.00, Lighting Adapt switched on, Adjust Start (Execute), Adjust Timeout 600.
8.1.6 Set Mirror X
The device supports the mirror X function. If this function is enabled, the image will be reversed in a horizontal way.
Go to Image Settings, click All Features, and you can see the Mirror X.
Note: This function is enabled by default, and it may differ by device models.
8.1.7 Set Test Pattern
Test pattern helps troubleshooting image problems and images in the test pattern are only for test. When exceptions occur in images acquired by the device in real time, you can check if images in the test pattern have similar problems to determine the cause of an exception.
- The test pattern is available in the test or raw device mode.
- Specific parameters of this function may differ by device models.
Go to Image Settings, click All Features, find Test Pattern in Other Features, and set Test Pattern according to actual demands.
Słowa kluczowe
8.2Hikrobot Code Algorithm Settings
8.2.1 Add CodeAdding code before you set code parameters via the client software. In Algorithm Settings, you can add different types of codes according to actual demands.In Algorithm Settings, click Add Barcode, select the types of codes to be read, and set the 1D Code Number and 2D Code Number according to actual demands.
8.2.2 Set Code Reading ROIAlgorithm ROI (Region of Interest) allows the device to execute algorithms and read codes on the specific area you selected, and thus improving code reading efficiency.Currently, up to 4 ROIs can be configured, and the device outputs codes according to the number of ROI (e.g. Region 1, Region 2, and Region 3) in turn. The client software supports drawing single group of ROI, drawing ROI in batch, and drawing ROI via chessboard.
Draw Single Group of ROISteps1. Go to Algorithm Settings, click All Features, and find Algorithm ROI.2. Click Draw to draw ROI in the live view window.3. (Optional) Repeat the above step to draw multiple ROIs according to actual demands
4. (Optional) Set other ROI parameters according to actual demands.● ROI Index: It indicates different ROIs and ranges from 0 to 149 which corresponds 1 to 150 ROIs.● Draw ROI Width: It refers to the width in algorithm ROI.● Draw ROI Height: It refers to the height in algorithm ROI.● Draw ROI Offset X: It refers to the X coordinate of the upper left corner in algorithm ROI.● Draw ROI Offset Y: It refers to the Y coordinate of the upper left corner in algorithm ROI.
5. (Optional) Click Execute in Restore Max. Algorithm ROI to restore the ROI to the full screen.6. (Optional) Click Execute in Clear All ROI to delete all ROIs.7. (Optional) Enable ROI Link IO Enable in Algorithm Control, and there will be prompts by the output device when codes are not read in any ROI.
Draw ROI in BatchSteps1. Go to Algorithm Settings, click All Features, and find Algorithm ROI.2. Click Batch to set parameters according to actual demands.● Area Offset: It sets the pixel quantity from the starting point when the ROI is in horizontal and vertical direction from the full resolution.● Area Size: It sets the pixel quantity in the horizontal and vertical direction of the ROI.● ROI Number: It sets the row and column quantity.● Row Spacing: It sets the interval between rows.● Column Spacing: It sets the interval between columns.3. Click OK after settings.4. Repeat other optional steps mentioned in drawing single group of ROI according to actual demands.
5. (Optional) Enable ROI Link IO Enable in Algorithm Control, and there will be prompts by the output device when codes are not read in any ROI.
Draw ROI via ChessboardSteps1. Go to Algorithm Settings, click All Features, and find Algorithm ROI.2. Click Execute in Chessboard ROI, set parameters according to actual demands, and click OK after setting.
3. Click after creating ROI, and the red frame becomes green as shown below.
4. (Optional) Click 
to restore the ROI to the full screen, and click 
to clean all configured ROIs.5. Repeat other optional steps mentioned in drawing single group of ROI according to actual demands.6. (Optional) Enable ROI Link IO Enable in Algorithm Control, and there will be prompts by the output device when codes are not read in any ROI.
8.2.3 Set 1D Algorithm ParameterClick All Features on the upper-right to display all algorithm parameters. In the Algorithm Parameter page, select 1DCode as Arithmetic Type, and then you can set its corresponding parameters.
Timeout ValueTimeout value refers to the maximum running time of algorithm, and its unit is ms. The code reader will stop parsing the images and return results if the time is exceeded the waiting time configured.Code ColorIt defines the readable code color. White Code On Black Wall means that the client software can recognize the white code with black background. Black Code On White Wall means that the client software can recognize the black code with white background.Code 39 CheckEnable this parameter if Code 39 uses the parity bit.
ITF 25 CheckEnable this parameter if ITF 25 uses the parity bit.
Code Score EnableIf it is enabled, the device will evaluate code quality and display overall grade and code score in history record area of the client software. The higher the score, and the better the code quality.Accurate Timeout EnableIf it is enabled, the accuracy of algorithm timeout will improve.
8.2.4 Set 2D Algorithm ParameterClick All Features on the upper-right to display all algorithm parameters. In the Algorithm Parameter page, select 2D Code as Arithmetic Type, and then you can set its corresponding parameters.
Timeout ValueTimeout value refers to the maximum running time of algorithm, and its unit is ms. The code reader will stop parsing the images and return results if the time is exceeded the waiting time configured.Algorithm Running ModeIt is used to be set the algorithm operating mode. It includes High Speed, High Performance, and Balance. High Speed focuses on recognition speed, and the algorithm can recognize the code rapidly, while High Performance refers to the algorithm can recognize the code that has distortion, spot or white gap, but its recognition speed is slow. Balance refers to the algorithm makes a balance between speed and performance.2D Code Max. SizeIt refers to the max. recognizable code width. The 2D code will not be recognized if its width exceeds the configured value.Mirror ModeIt is useful when the recognizedID3000, image is a mirror one, mirroring in X coordinate. 3 modes are available: Adaptive, Mirror, and Non Mirror.Downsampling LevelIt refers to the pixel sample size that the code reader takes. Increasing this parameter will improve the code reading efficiency at the expense of code recognition rate.
Code ColorIt defines the readable code color. Adaptive means that the client software can recognize both the black code with white background, and the white code with black background. White Code On Black Wall means that the client software can recognize the white code with black background. Black Code On White Wall means that the client software can recognize the black code with white background.
Note● For QR code, the code color is determined by the color of the concentric square on it. indicates that the code color is white, and indicates that the code color is black.
● For DM code, the code color is determined by the color of its "L" shaped sides. White "L" shaped sides indicate that the code color is white, and black "L" shaped sides indicate that the code color is black.
Discrete FlagContinuous stands for the minimum units in the "L" shaped sides of the DM code are continuous, or the minimum units in the concentric square like or in the QR code are continuous. Usually the continuous code uses squares as the minimum units. Discrete stands for the minimum units in the "L" shaped sides of the DM code are discrete, or the minimum units in the concentric square like or in the QR code are discrete. Usually the discrete code uses dots as the minimum units. Adaptive stands for the device can recognize both continuous code and the discrete code.QR Distortion CorrectionIf the QR code or DM code is distorted, you can enable this parameter to improve code recognition rate.
Advance ParamThis parameter is applicable to some special codes, and it is recommended to use the default value.DM Code ShapeIt defines the recognizable code shape. Square stands for square mode: If the 2D code is square shaped, it can be recognized by the device. Rectangle stands for rectangle mode: If the 2D code is rectangle shaped, it can be recognized by the device. Adaptive stands for compatible mode: The device can recognize 2D codes of both the abovementioned two shapes.DM Code TypeIt includes All, ECC140, and ECC200.2D Code Quality EnableRefer to section Set 2D Code Quality Evaluation for details.Code Score Enable If it is enabled, the device will evaluate code quality and display overall grade and code score in history record area of the client software. The higher the score, and the better the code quality.Accurate Timeout EnableIf it is enabled, the accuracy of algorithm timeout will improve.
8.2.5 Set 2D Code Quality EvaluationAfter 2D Code Quality Enable, you can set specific parameters according to actual demands.
Steps1. Set Sym Proc Type according to actual demands, and the default type is Type 1. Type 1 has a strong capacity to locate codes.2. Set Iso Edition, including Iso15415 and Iso29158● Iso15415 is applicable to the quality evaluation for label 2-dimensional codes.● Iso29158 is applicable to the quality evaluation for DPM format 2-dimensional codes.3. Set Verify Edition, including standard mode and HIK mode.● Standard mode is a standard quality evaluation mode.● HIK mode is a professional quality evaluation mode.4. Set Standard Aperture and Magnification.● Standard aperture refers to a standard aperture, and its default value is 400.● Magnification is 150 by default.
5. Click 
to start acquisition, and the client software will display the overall code quality in the history area.
6. (Optional) Click specific grade in the overall grade list to view different quantity evaluation items.
8.2.6 Set Code ScoreAfter enabling code score function, the client software can output specific score for codes it has read.
Steps1. Right click the device in Device Connection, and click Feature Tree.2. Go to Algorithm Control, and enable Code Score Enable.
3. Click 
to start acquisition, and the client software will display specific code score in the history area.
4. (Optional) Go to Image Settings, and adjust parameters likesettings, exposure time, gain, Gamma, acquisition frame rate, burst frame count, polling, light source, etc. if the code score is low.
8.3 Signal Input SettingsIn the signal input module, you can set the trigger related parameters. You can enable trigger mode to let the acquisition of image data occur only when the trigger source is generated.
8.3.1 Set Trigger ModeThe device has 2 types of trigger mode: Internal trigger mode and external trigger mode.Internal Trigger ModeIn this mode, the device acquires images via its internal signals.External Trigger ModeIn this mode, the device acquires images via external signals like software signal and hardware signal. The trigger source of external trigger mode includes software, physical lines, counter, TCP, UDP, and serial.
8.3.2 Enable Internal Trigger ModeIn the internal trigger mode, the device acquires images via its internal signals. You have 2 methods to enable the internal trigger mode:● Click I/O Control Settings → Input → Trigger Mode, and select Off as Trigger Mode.● In the live view page, click 
to enable the internal trigger mode.
8.3.3 Enable External Trigger ModeIn the external trigger mode, the device acquires images via external signals like software signal and hardware signal. You have 2 methods to enable the external trigger mode:● Click I/O Control Settings → Input → Trigger Mode, and select On as Trigger Mode.● In the live view page, click 
to enable the external trigger mode.
Set and Execute Software Trigger ModeIn software trigger, the software sends trigger signal to the device via I/O interface to acquire images.Steps1. Click I/O Control Settings → Input → Trigger Mode.2. Select On as Trigger Mode.3. Select Software as Trigger Source.4. Click Execute in Trigger Source to send trigger commands.You can also enter Auto Trigger Time, and then enable Enable Auto Trigger to let the client software automatically send trigger signal to device according to the interval you set.
Set and Execute Hardware Trigger ModeSteps1. Click I/O Control Settings → Input → Trigger Mode.2. Select On as Trigger Mode.3. Select the specific line as Trigger Source according to actual demands.4. Set Debounce Time and Line Out Trigger In Polarity according to actual demands.
Set and Execute Counter Trigger ModeCounter specifies that the trigger source will be generated after the set number of valid signals appears. For example, if you set the Count Number to 3, the trigger source will be generated after 3 signals appear.Steps1. Click I/O Control Settings → Input → Trigger Mode.2. Select On as Trigger Mode.3. Select Counter 0 as Trigger Source.4. Set Trigger Delay, Count Number, Count Source and Line Out Trigger In Polarity according to actual demands.
Set and Execute TCP Trigger ModeTCP start specifies the TCP server as the source for the trigger signal. When the server receives the specified string text, the trigger signal will be outputted.Click I/O Control Settings → Input → Trigger Mode, select On as Trigger Mode and select TCP Start as Trigger Source.Set Trigger Delay, Tcp Trigger Port, and Tcp Start Trigger Text according to actual demands.
Set and Execute UDP Trigger ModeUDP start specifies the UDP server as the source for the trigger signal. When the server receives the specified string text, the trigger signal will be outputted.Click I/O Control Settings → Input → Trigger Mode, select On as Trigger Mode and select UDP Start as Trigger Source.Set Trigger Delay, Udp Trigger Port, and Udp Start Trigger Text according to actual demands.
Set and Execute Serial Port Trigger ModeSerial start specifies the serial port as the source for the trigger signal. When the serial port receives the specified string text, the trigger signal will be outputted.Click I/O Control Settings → Input → Trigger Mode, select On as Trigger Mode and select Serial Start as Trigger Source.Set Trigger Delay, Serial Baudrate, Serial Data Bits, Serial Parity, Serial Stop Bits, and Serial Start Trigger Text according to actual demands.
Set and Execute Self Trigger ModeSelf trigger mode allows you to trigger the device according to the trigger period you configured.Steps1. Click I/O Control Settings → Input → Trigger Mode.2. Select On as Trigger Mode.3. Select Self Trigger as Trigger Source, and set Self Trigger Period and Self Trigger Count.4. Click Execute in Self Trigger Start to start, and click Execute in Self Trigger Stop to stop.
8.3.4 Stop TriggerThe device supports stopping trigger via TCP, UDP, I/O, and serial port. You can also set code reading timeout duration or max. barcode amount to be read to stop trigger. After stopping trigger is completed, the device cannot make response to trigger again.Stop Trigger via IOYou can stop a trigger via IO: Enabling IO Stop Trigger Enable first, select specific sources from IO Stop Trigger Selector, and then set the trigger polarity as the condition to stop trigger.
When selecting SoftwareTriggerEnd as IO Stop Trigger Selector, you can click Execute in Software Stop Trigger to stop current trigger.
Stop Trigger via SerialWhen the specified serial port receives the specified string text, the trigger will be stopped.The client software sends stop trigger command to the device after Serial Stop Trigger Enable is enabled.You should enter Serial Stop Trigger Text, Serial Baudrate, Serial Data Bits, Serial parity, and Serial Stop Bits according to actual demands. The Serial Baudrate includes 4800, 9600, 19200, 38400, 57600 and 115200, and Serial Data Bits is 8.
Stop Trigger via UDPWhen the UDP server receives the specified string text, the trigger will be stopped. The client software sends stop trigger command to the device after Udp Stop Trigger Enable is enabled. You should enter Udp Trigger Port and Udp Stop Trigger Text according to actual demands. The range of Udp Trigger Port is from 1025 to 65535, and the default port is 2002.
Stop Trigger via TCPWhen the TCP server receives the specified string text, the trigger will be stopped. The client software sends stop trigger command to the device after Tcp Stop Trigger Enable is enabled. You should enter Tcp Trigger Port and Tcp Stop Trigger Text according to actual demands. The range of Tcp Trigger Port is from 1025 to 65535, and the default port is 2001.
Stop Trigger via Timeout Duration
When the trigger time reaches the specified maximum value (in ms), the trigger will be stopped. You can enable TimeOut Stop Trigger Enable, and set Maximum Output LimitedTime according to actual demands. The range of Maximum Output Limited Time is 0 to 10000 ms.
Stop Trigger via Code Number
This function means that the code quantity outputted by the device is restricted to the settings you configured here. You can enable CodeNum Stop Trigger Enable, and set CodeNum Stop Trigger Min and CodeNum Stop Trigger Max according to actual demands.● If the outputted code quantity is smaller than configured CodeNum Stop Trigger Min, and the device will output codes continuously.● If the outputted code quantity is smaller than configured CodeNum Stop Trigger Max, and the device will stop outputting codes.● If the outputted code quantity is between configured CodeNum Stop Trigger Min and CodeNum Stop Trigger Max, and the device will read and output codes according to trigger signals.● If CodeNum Stop Trigger Min is same with CodeNum Stop Trigger Max, and the device will stop outputting codes when the number of outputted codes reaches the configured number.
8.4 Signal Output Settings8.4.1 Select Output SignalThe device’s output signal can control external devices like PLC, flashingaiming light, etc.strobe, Clicklens I/Ofocus, Controlauto Settingsfocus, →self-adaptive Outputadjustment, →mirror LineX, Outtest Selector to select output signal.
pattern
8.4.2 Enable Line InverterThe level inverter function allows the device to invert the electrical signal level of an I/O line, and meets requirements of different devices for high or low electrical signal level.You can go to I/O Control Settings → Output → Line Out Inverter to enable it.
8.4.3 Set Event SourceThe device supports outputting different trigger signals according to the event source you select.Click I/O Control Settings → Output → Line Out Activation Event to select event source.The device supports following event sources, including Off, Acquisition Start Active, Acquisition Stop Active, Frame Burst Start Active, Frame Burst Stop Active, Exposure Start Active, Soft Trigger Active, Hard Trigger Active, Counter Active, Timer Active, No Code Read, Read Success, and Light Strobe Long.
Select Acquisition Start ActiveIf acquisition starts, the output signal will be triggered. When you select Acquisition Start Active as Line Out Activation Event, you can set its output delay time and duration.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.
Select Acquisition Stop ActiveIf acquisition stops, the output signal will be triggered. When you select Acquisition Stop Active as Line Out Activation Event, you can set its output delay time and duration.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.
Select Frame Burst Start Active
If the burst of a frame starts, the output signal will be triggered. When you select Frame Burst Start Active as Line Out Activation Event, you can set its output delay time and duration.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.
Select Frame Burst Stop Active
If the burst of a frame stops, the output signal will be triggered. When you select Frame Burst Stop Active as Line Out Activation Event, you can set its output delay time and duration.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.
Select Exposure Start Active
If you select Exposure Start Active as Line Out Activation Event, you can set its output delay time, duration, and ahead time.Line Out Delay TimeIt sets the delay time for outputting the signal.Line Out DurationIt sets the duration for outputting the signal.
Line Out Ahead TimeIt sets the ahead time for outputting the signal.
Select Soft Trigger ActiveIf you select Soft Trigger Active as Line Out Activation Event, you can set its output delay time, duration, and execute outputting signal manually.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.Line Trigger SoftwareClick Execute for manually outputting the output signal.
Select Hard Trigger ActiveIf you select Hard Trigger Active as Line Out Activation Event, you can set its output delay time, duration, trigger source, and trigger activation.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.Hardware Trigger SourceIt sets the hardware trigger source, including LineIn 0, LineIn 1, and LineIn 2.Hardware Trigger ActivationIt sets the trigger activation of input signal, including Rising Edge and Falling Edge.
Select Counter ActiveCounter active means that the counter triggers the output signal. When you select Counter Active as Line Out Activation Event, you can set its output delay time and duration.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.
Select Timer ActiveIf you select Timer Active as Line Out Activation Event, you can set its output duration and period.Line Out DurationIt sets the time duration of the output signal.Line Out PeriodIt sets the time period of the output signal.
Select No Code ReadIf you select No Code Read as Line Out Activation Event, you can set its output delay time and duration.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.
Select Read SuccessIf you select Read Success as Line Out Activation Event, you can set its output delay time and duration.Line Out Delay TimeIt sets the delay time for outputting the output signal.Line Out DurationIt sets the time duration of the output signal.
Select Light Strobe LongIf you select Light Strobe Long as Line Out Activation Event, you do not need to set any parameters.
8.5 Code Reading Result SettingsIn Data Processing module, you can set filter rules for reading barcodes and other data processing related parameters.
8.5.1 Set Code Reading Result Output ModeThere are 2 types of output modes when the device mode is Normal and trigger mode is On: Instant output mode and non-instant output mode.● Instant output mode means that the device can instantly output code reading results when recognizing codes if you enable Instant Output Mode Enable in Filter Rule.● Non-instant output mode means that the device does not output code reading results it recognized until the trigger stops if Instant Output Mode Enable is not enabled. If the device does not recognize any codes during the whole process, images it captured will be output, and you can set which images to be outputted in NoRead Image Index.When the device mode is Normal and trigger mode is Off, you can set Filter Time in Filter Rule. Within the configured Filter Time, the device will not output any code information
8.5.2 Set Filter RuleYou can set rules to filter unwanted barcodes to improve the reading efficiency in Filter Rule.Two filter modes are available, including normal mode and regular expression mode. You can set it in Filter Mode.
Normal Filter ModeWhen the device mode is Normal, Trigger Mode is On, and Filter Mode is Normal, you can set the following parameters according to actual demands.Instant Output Mode EnableIf this parameter is enabled, the device can instantly output code reading result when recognizing codes. If it is not enabled, the device will not output code reading result until the trigger stops.Min. Output TimeIt sets the min. waiting time before data output. For example, if you set 500 ms as Minimum Output Time, the barcode would not be outputted until 500 ms is passed.Numeral FilterIf this parameter is enabled, the device will only parse and read the numeral contents of the barcodes, and the non-numeral contents will be filtered out.Max Output LengthIt sets the max. code length that can be outputted.Code Offset NumIt sets the range of barcode to be filtered. For example, the barcode is ABCDEFG, if you set this parameter as 2, the device will output CDEFG at last and filter AB.Begin with Specific Character for ResultIf this parameter is enabled, the device will only read the barcodes which begin with a specific character. Otherwise, the barcodes will be filtered out. You can enter the specific character in Begin with.Include Specific Character in BarcodeIf this parameter is enabled, the device will only read the barcodes which include a specific character. Otherwise, the barcodes will be filtered out. You can enter the specific character in Character.Exclude Specific Character in BarcodeIf this parameter is enabled, the device will only read the barcodes which exclude a specific character. Otherwise, the barcodes will be filtered out. You can enter the specific character in Character.Min. Code LengthIf the length of a barcode is shorter (in terms of the number of characters contained in the barcode) than the configured value, the device will not parse the contents of the barcode. The valid value is from 1 to 256. For example, if you set the value as 6, the device will not parse the contents of the barcodes which contain less than 6 characters.Max. Code LengthIf the length of a barcode is longer ((in terms of the number of characters contained in the barcode) than the configured value, the device will not parse the contents of the barcode. The valid value is from 1 to 256. For example, if you set the value as 9, the device will not parse the contents of the barcodes which contain more than 9 characters.Read Times ThresholdIf the reading results of a barcode is same for the configured times, the barcode will be regarded as valid and its reading result will be outputted. Or the barcode will be regarded as invalid and its reading result will not be outputted.De-duplication EnableIf it is enabled, the repeated code information will be filtered within specific trigger times. You can set trigger times in De-duplication Windows Size, and its default value is 1.De-duplication By ROIIf it is enabled, the device will filter information based on drawn ROIs.
Regular Expression Filter ModeInstant Output Mode EnableIf this parameter is enabled, the device can instantly output code reading result when recognizing codes. If it is not enabled, the device will not output code reading result until the trigger stops.Min. Output TimeIt sets the min. waiting time before data output. For example, if you set 500 ms as Minimum Output Time, the barcode would not be outputted until 500 ms is passed.Max Output LengthIt sets the max. code length that can be outputted.Code Offset NumIt sets the range of barcode to be filtered. For example, the barcode is ABCDEFG, if you set this parameter as 2, the device will output CDEFG at last and filter AB.Regular ExpressionIt selects the regular expression from order 1 to order 10. You can enter specific regular expression contents in Regular Expression Filter. Up to ten regular expression rules can be set at the same time. Once one regular expression is met, code can be outputted.Regular Expression FilterIt sets the specific regular expression contents.Min. Code LengthIf the length of a barcode is shorter (in terms of the number of characters contained in the barcode) than the configured value, the device will not parse the contents of the barcode. The valid value is from 1 to 256. For example, if you set the value as 6, the device will not parse the contents of the barcodes which contain less than 6 characters.Max. Code LengthIf the length of a barcode is longer ((in terms of the number of characters contained in the barcode) than the configured value, the device will not parse the contents of the barcode. The valid value is from 1 to 256. For example, if you set the value as 9, the device will not parse the contents of the barcodes which contain more than 9 characters.Read Times ThresholdIf the reading results of a barcode is same for the configured times, the barcode will be regarded as valid and its reading result will be outputted. Or the barcode will be regarded as invalid and its reading result will not be outputted.
8.5.3 Set Result FormatResult format settings allow you to set the format and contents contained in the outputted barcode information. Result format is related to communication protocol and trigger mode.With different selected communication protocol and trigger mode, you need to set corresponding parameters.
Result Output via Smart SDKWhen the communication protocol is Smart SDK, device mode is Normal and trigger mode is On, you can set following parameters.Sorting RulesIt decides the output order of codes, and you can select it according to actual demands.One By One EnableIf it is enabled, the device will send one piece of code information each time in accordance with the specified interval. You can set the interval via One By One Interval and the default value 100 ms.Local Save Picture ModeIt includes Off and NoRead. You can select NoRead to let the device save images when no code is read.Local Picture TypeIt sets the image saving type, including JPEG and BMP.Local Override StrategyIt includes Off, Max Count, Loop Max Count, and Reserve Space. Off means that disk will not be overridden. Max Count means that the device will save image quantity configured in Local Override Max. Count, and no more imaged will be saved when the disk is full. Loop Max Count means that after the image quantity is reached the number configured in Local Override Max. Count, the device will delete the first image and continue to save the latest image. Reserve Space means that the device will save images when the disk is safe in terms of storage space If the available disk space is lower than configured value, and images will be deleted.Local Override Max. CountYou need to set this parameter when selecting Max Count or Loop Max Count as Local Override Strategy.Local Picture Name ContentIt selects what contents you want to display in file name, including frame time, trigger No. and frame No.Local Time FormatIt selects a format type from the drop-down list for the time stamp contained in the file name. Take YYYYMMDD_HHMMSSFFF as an example, (from the left to the right) YYYY represents year, MM represents month, DD represents date, HH represents hour, MM represents minute, SS represents second, and FFF represents millisecond.Local Save Picture StrategyIt sets the picture saving method. Four methods are available, including recently frame, all frames, range frames and specific frame. If specific frame is selected as Local Save Picture Strategy, you need to set Local Picture Index.
Result Output via FTPThe device also supports using the FTP communication protocol to send and receive data, and you can select it to output information. The configurable parameters below are related to the trigger mode, and here we take the external trigger mode as an example.
Sorting RulesIt decides the output order of codes, and you can select it according to actual demands.One By One EnableIf it is enabled, the device will send one piece of code information each time in accordance with the specified interval. You can set the interval via One By One Interval and the default value 100 ms.Local Save Picture ModeIt includes Off and NoRead. You can select NoRead to let the device save images when no code is read.Local Picture TypeIt sets the image saving type, including JPEG and BMP.Local Override StrategyIt includes Off, Max Count, Loop Max Count, and Reserve Space. Off means that disk will not be overridden. Max Count means that the device will save image quantity configured in Local Override Max. Count, and no more imaged will be saved when the disk is full. Loop Max Count means that after the image quantity is reached the number configured in Local Override Max. Count, the device will delete the first image and continue to save the latest image. Reserve Space means that the device will save images when the disk is safe in terms of storage space If the available disk space is lower than configured value, and images will be deleted.Local Override Max. CountYou need to set this parameter when selecting Max Count or Loop Max Count as Local Override Strategy.Local Picture Name ContentIt selects what contents you want to display in file name, including frame time, trigger No. and frame No.Local Time FormatIt selects a format type from the drop-down list for the time stamp contained in the file name. Take YYYYMMDD_HHMMSSFFF as an example, (from the left to the right) YYYY represents year, MM represents month, DD represents date, HH represents hour, MM represents minute, SS represents second, and FFF represents millisecond.Local Save Picture StrategyIt sets the picture saving method. Four methods are available, including recently frame, all frames, range frames and specific frame. If specific frame is selected as Local Save Picture Strategy, you need to set Local Picture Index.Output Retrans EnableIf this parameter is enabled, the data is allowed to retransmit to FTP server, and you should set specific value in Output Retrans Number.
FTP Picture Name ContentIt selects what contents you want to display in FTP file name, including code content, code type, frame number, etc. You can select multiple contents as desired, and the selected contents will be displayed below.FTP Transmission ConditionsIt sets the condition to upload the data outputted by the device to FTP server. All refers to upload the data always. Read Barcode refers to upload the data only when the barcode is read by the device. No Read Barcode refers to upload the data only when no barcode is read by the device.FTP Transmission Result ContainIt selects contents to upload to the FTP server. Just Result refers to only upload the content of the barcode. Just Picture refers to only upload the barcode picture. Result and Picture refers to upload both the content of the barcode and the picture.FTP Time FormatIt selects a format type from the drop-down list for the time stamp contained in the file name. Take YYYYMMDD_HHMMSSFFF as an example, (from the left to the right) YYYY represents year, MM represents month, DD represents date, HH represents hour, MM represents minute, SS represents second, and FFF represents millisecond.FTP Result PrefixIt sets the prefix of FTP file name, including No, Result and All. No stands for no prefix for file name, and all images are saved in FTP root directory. Result stands for all images that code reading successfully will be saved in Read directory, and all images that code reading failed will be saved in Noread directory. All stands for all images will be saved in All directory.FTP Save Picture StrategyIt sets the FTP picture saving method when no code is read. Four methods are available, including recently frame, all frames, range frames and specific frame. If specific frame is selected as FTP Save Picture Strategy, you need to set FTP Picture Index.Result Output via Other Communication ProtocolsWhen the communication protocol is TCP Client, TCP Server, Serial, Profinet, Melsec, Ethernet/IP, ModBus, Fins or SLMP, device mode is Normal and trigger mode is On, you can set following parameters.
Sorting RulesIt decides the output order of codes, and you can select it according to actual demands.One By One EnableIf it is enabled, the device will send one piece of code information each time in accordance with the specified interval. You can set the interval via One By One Interval and the default value 100 ms.ROI Output NoRead EnableIf it is enabled, codes will be outputted in turn according to the ROI Selector of the algorithm ROI they belong.Local Save Picture ModeIt includes Off and NoRead. You can select NoRead to let the device save images when no code is read.Local Picture TypeIt sets the image saving type, including JPEG and BMP.Local Override StrategyIt includes Off, Max Count, Loop Max Count, and Reserve Space. Off means that disk will not be overridden. Max Count means that the device will save image quantity configured in Local Override Max. Count, and no more imaged will be saved when the disk is full. Loop Max Count means that after the image quantity is reached the number configured in Local Override Max. Count, the device will delete the first image and continue to save the latest image. Reserve Space means that the device will save images when the disk is safe in terms of storage space If the available disk space is lower than configured value, and images will be deleted.Local Override Max. CountYou need to set this parameter when selecting Max Count or Loop Max Count as Local Override Strategy.Local Picture Name ContentIt selects what contents you want to display in file name, including frame time, trigger No. and frame No.Local Time FormatIt selects a format type from the drop-down list for the time stamp contained in the file name. Take YYYYMMDD_HHMMSSFFF as an example, (from the left to the right) YYYY represents year, MM represents month, DD represents date, HH represents hour, MM represents minute, SS represents second, and FFF represents millisecond.Local Save Picture StrategyIt sets the picture saving method. Four methods are available, including recently frame, all frames, range frames and specific frame. If specific frame is selected as Local Save Picture Strategy, you need to set Local Picture Index.Profinet Output FormatIt selects what contents you want to output, including code content, code type, angle, trigger start time, code score, etc. You can select multiple contents according to actual demands.Profinet Format CheckYou should click Execute in Profinet Format Check to check if you entered is right in format, and the check result will be displayed in Profinet Format Check Result.Profinet Output NoReadIf it is enabled, and the device will output the content you set in Profinet Output NoRead Text when no code is recognized.Profinet Output Start TextThe contents of the start part of the data outputted. You can set the contents accordingto actual condition.Profinet Output Stop TextThe contents of the end part of the data outputted. You can set the contents according to actual condition.Profinet Output Barcode Enter Character EnableIf it is enabled, enter character will be outputted.Profinet Output Barcode Newline Character EnableIf it is enabled, a newline will be outputted.Profinet Output Barcode Carriage Return EnableIf it is enabled, a carriage return will be outputted.Profinet Add NoRead EnableYou can add contents to let the device output codes when the code recognized by the device does not meet the min. length requirement. It includes Off, Add Noread, and Just Noread. Off does not add contents and the device outputs code recognized only. Add Noread allows you to add contents to the min. length requirement and output. Just Noread means that the device outputs Noread only if the code recognized by the device does not meet the min. length requirement.Code Pos Width EnableIf it is enabled, you can add 0 to codes if the code coordinate does not meet specified length.Code Pos WidthYou can enter the length of the code coordinate after enabling Code Pos Width Enable.CodeNum End Trigger MinIf it is enabled, the device will stop triggering and save the current image when the code recognized by the device does not meet the min. length requirement.
8.6 Contrast Control Settings
The contrast control function compares the data that the device reads with preset data and outputs contrast result. The result can be used as the event source of trigger signal, including Contrast Success and Contrast Fail. This function has two ways to contrast, including regular contrast and consecutive number contrast.Regular ContrastThe regular contrast requires you to set code contents in advance, and the client software will contrast the data that the device reads with preset contents and outputs comparison result.Steps1. Right click the device in Device Connection, and click Feature Tree.2. Go to Contrast Control, enable Contrast Enable, and select Regular as Contrast Rules.3. Set Start Position that means the stating position of the comparison.4. Set Character Number that means the comparison quantity.5. Set code contents in Wildcard String.
Consecutive Number ContrastThe consecutive number contrast requires you to set consecutive code rules, and the client software will contrast the data that the device reads with preset rules and outputs contrast result.Steps1. Right click the device in Device Connection, and click Feature Tree.2. Go to Contrast Control, enable Contrast Enable, and select Consecutive Number as Compare Rules.3. Set Start Position that means the stating position of the comparison.4. Set Digital Number that means the comparison quantity.5. Set Step that means the client software will increase or decrease the preset value after each comparison according the step you set.
6. (Optional) Click Execute in Contrast Reset to reset comparison. After that, the client software will use the first code it reads as the preset value.Here we take start position (3), digital number (2) and step (2) as an example to explain the consecutive number comparison:● If the first code that the device reads is ur96k, and then the preset value is 96. The preset value increases to 98 (96+2).● If the second code is yr98kjkfd, and comparison succeeds. The preset value increases to 100 (98+2).● If the third code is kl99fjkd, and comparison fails. The preset value does not increase.● If the fourth code is kl00djf, and comparison succeeds. The preset value increases to 02 (00+2).
8.7 Communication SettingsThe communication protocol is used to transmit and output code reading result and image. The communication protocol is related to the device modes. With various device modes, the device supports different communication protocols and corresponding parameters. When the device mode is Test or Raw, the device only supports Smart SDK protocol and no parameter settings are required. While in Normal mode, the device supports Smart SDK, TCP Client, TCP Server, Serial, FTP, Profinet, Melsec, Ethernet/IP, ModBus, Fins and SLMP communication protocols, and you need to set corresponding parameters.
8.7.1 Smart SDKIf Smart SDK is selected as the Communication Protocols, you can enable SmartSdk Protocol to let the device output data via Smart SDK.Encode JPG FlagIf enabled, the device will compress the image data.Quantity of JpgYou can enter a number (range: 50 to 99) to determine the compression quality
8.7.2 TCP ClientThe TCP includes TCP Server and TCP Client. If TCP Client is selected as the Communication Protocols, you can enable TCP Protocol, and enter TCP Dst Addr and TCP Dst Port.
8.7.3 TCP ServerThe TCP includes TCP Server and TCP Client. If TCP Server is selected as the Communication Protocols, you can enable TCP Server Enable, and enter TCP Server Port.
8.7.4 SerialIf Serial is selected as the Communication Protocols, you can enable Serial Protocol, enter Serial Baud Rate, Serial Data Bits, Serial Parity, and Serial Stop Bits.
8.7.5 FTPIf FTP is selected as the Communication Protocols, you can enable FTP Protocol, enter FTP Host Addr, FTP Host Port, FTP User Name, and FTP User PWD.
8.7.6 ProfinetIf Profinet is selected as the Communication Protocols, you can enable Profinet Enable and set Profinet Device Name according to actual demands.
8.7.7 MELSECIf MELSEC is selected as the Communication Protocols, you can enable MELSEC Protocol Enable and set related parameters according to actual demands.MELSEC Destination AddressIt sets the IP address of the target PLC.MELSEC Destination PortIt sets the port number of the target PLC.MELSEC Data Base AddressIt sets the first address of the data area.MELSEC State Base AddressIt sets the first address of the status area.MELSEC Network NumberIt sets the network No.MELSEC PLC NumberIt sets the PLC No.MELSEC Module I/O NumberIt sets the target module’s I/O number.MELSEC Module Station NumberIt displays the module station number.MELSEC TimeoutIt sets the waiting time before the returning of PLC’s response.
8.7.8 Ethernet/IPIf Ethernet/IP is selected as the Communication Protocols, you can enable Ethernet/IP Enable, and the device will output data via Ethernet/IP.
8.7.9 ModBusIf ModBus is selected as the Communication Protocols, you can enable ModBus Enable and set related parameters according to actual demands.ModBus ModeIt includes server and client, and is server by default.
ModBus Control Address SpaceIt is holding_register by default.ModBus Control Address OffsetIt refers to the address offset, and is 0 by default.ModBus Control Data NumberIt is 2 by default.ModBus State Address SpaceIt is input_register by default.ModBus State Address OffsetIt is 0 by default.ModBus State Data NumberIt is 2 by default.ModBus Result Address SpaceIt is input_register by default.ModBus Result Address OffsetIt is 4 by default.ModBus String Byte SwapIf it is enabled, string byte is saved by big-endian. If it is not enabled, string byte is saved by little-endian.
8.7.10 FinsIf Fins is selected as the Communication Protocols, you can enable Fins Enable and set related parameters according to actual demands.
Fins Communication ModeIt includes UDP or TCP.Fins Local PortIt is 9600 by default.Fins Dst IPIt sets the IP address of the target device.Fins Dst PortIt sets the port of the target device.Fins Data FormatIt includes 16-bit or 32-bit.Fins Scan Rate (ms)It sets the interval that the device reads the server’s control register, and the unit is ms.Fins Control AreaIt is saved in DM area by default.Fins Control AddrYou can set it according to actual demands. Make sure that each area cannot be overlapped and covered.Fins State AreaIt is saved in DM area by default.Fins State AddrYou can set it according to actual demands. Make sure that each area cannot be overlapped and covered.Fins Result AreaIt is saved in DM area by default.Fins Result AddrYou can set it according to actual demands. Make sure that each area cannot be overlapped and covered.
8.7.11 SLMPIf SLMP is selected as the Communication Protocols, you can enable SLMP Enable and set related parameters according to actual demands.SLMP Dst AddrIt sets the IP address of the target PLC.SLMP Dst PortIt sets the port number of the target PLC.SLMP Data Base AddrIt sets the first address of the data area.SLMP State Base AddrIt sets the first address of the status area.SLMP Network NumIt sets the network No.SLMP PLC NumIt sets the PLC No.SLMP Module I/O NumIt sets the target module’s I/O number.SLMP Module Station NumIt displays the module station number.SLMP TimeoutIt sets the waiting time before the returning of PLC’s response.
8.8 User Set CustomizationThe Configuration Management module allows you to set and manage the user set. A user set is a group of parameter values with all the settings needed to control the device, and you can save, load and switch different user sets.Save SettingsIf you have set the device parameters as desired, you can save them into the user set. Go to Config Management → Save Settings, and click UserSet1, UserSet2, or UserSet3 to save the current device settings.Load SettingsYou can load the user set to restore the device to the saved group of parameter values again if required. Go to Config Management → Load Settings, and click Default, UserSet1, UserSet2, or UserSet3 to load settings.
Start SettingsThe selected user set will be automatically loaded after the device being powered on.For example, if you select Default, the device parameter settings will be restored to the factory settings.
8.9 Statistics InformationThe statistics information in the feature tree helps you to count data related with code reading.
Go to feature tree, find Statistics Info., and select Statistics Mode according to actual demands. Two statistics modes are available:All Frames means that the client software will display all data since the device is powered on. Latest Frames means that the client software will display data of the last 10 frames. Refer to the table below for specific parameters.
8.10 Event ReportThe diagnose event report function in the feature tree monitors memory and CPU usage rate, and let you know when there is a crash, higher CPU usage rate, insufficient memory, and other events.Go to feature tree, find Diagnose Event Report, and you can view related information as shown below. You can click Execute in Reset Event to clear all information.