11. FAQ (Frequently Asked Questions)
Streszczenie: Najczęstsze problemy z czytnikiem ID5000: ciemny obraz, niska liczba klatek w podglądzie, brak urządzenia na liście IDMVS, brak obrazu w podglądzie oraz nierozpoznawane kody – przyczyny i rozwiązania.
EN: ID5000 FAQ: dark image, low frame rate in live view, no device listed in IDMVS, no image in live view and codes not recognized – reasons and solutions.
Dotyczy: przemysłowy czytnik kodów Hikrobot serii ID5000 (złącze M12 12-pin, Gigabit Ethernet, RS-232; obsługa przez klienta IDMVS)
Źródło: dokumentacja producenta (Hikrobot ID5000 Series Industrial Code Reader User Manual, V2.5.0)
11.1 Why the imageImage isIs veryVery dark?
Dark?
Problem
All black or too dark during preview.
Reason
Too small adjustment value of exposure and gain, or the lens aperture is not opened enough.
Solution
Increase exposure and gain appropriately, or rotate the lens aperture to open largely.
11.2 Why the image'Image's frameFrame rateRate isIs veryVery lowLow in the liveLive view?
View?
Problem
Image incoherent/Low frame rate/Image tearing when adjusting the view preview.
Reason●
- The network may be Fast Ethernet.
● - Incorrect jumbo packet setting.
Solution●
- Check whether the network transmission speed is 1 Gbps and NIC is the gigabit NIC, etc.
● - Set jumbo packet value as 9 KB, or 9014 bytes.
11.3 Why thereThere isIs noNo deviceDevice listedListed afterAfter I runRun the IDMVS clientClient software?
Software?
Problem
Run IDMVS client, there is no listed device.
Reason●
- The device is powered off.
● - Network exception.
Solution●
- Check the device power connection (observe whether the PWR light is solid blue or not), to make sure the device is powered up normally.
● - Check the network connection (observe whether the LNK light is solid green or not and ACT light is flashing yellow or not) to make sure the device can be connected to the network normally. PC port and the device are in the same network segment.
11.4 Why thereThere isIs noNo imageImage in the liveLive view?
View?
Problem
No image in the live view.
Reason●
- Enabled trigger mode, but there is no trigger signal.
● - Incorrect device mode settings, and no codes are recognized within the field of view.
Solution●
- Disable the trigger mode.
● - Set the device mode as the test mode.
11.5 Why codesCodes withinWithin the fieldField of viewView cannotCannot beBe recognized?
Recognized?
Problem
Codes within the field of view cannot be recognized.
Reason
Correct code types are not selected in the Algorithm Settings, or incorrect settings in Filter Rule.
Solution●
- Go to Algorithm Settings → Add Barcode, and add different types of codes according to actual demands.
● - Go to Data Processing → Filter Rule, and adjust settings in Filter Rule according to actual demands.
Słowa kluczowe
Hikrobot ID5000, FAQ, troubleshooting, dark image, exposure, gain, aperture, frame rate, Gigabit Ethernet, jumbo packet, PWR, LNK, ACT, trigger mode, test mode, filter rule, diagnostyka