Appendix A: Quick Reference to the Variables

Streszczenie: Skrócona lista zmiennych napędu pogrupowanych według funkcji: tryby prądowe, prędkościowe i pozycyjne, bazowanie, limity i wzmocnienia pętli, filtry, zmienne bieżące, wejścia/wyjścia oraz rejestry statusu i stanu – identyfikator zmiennej i opis z jednostkami.
EN: Quick reference of drive variables grouped by function (variable ID, description, units).

Dotyczy: serwonapędy Copley Controls z interfejsem ASCII (RS-232, sieć multi-drop CAN), program CME 2
Źródło: dokumentacja producenta (Copley Controls ASCII Interface Programmer’s Guide); tabele przepisane z obrazów na tekst – opracowanie Multiprojekt

This chapter provides quick reference to the variables described in this manual. Contents include: 

A.1 Variables by Function

Programmed Current Mode Variables

Variable IDDescription
0x02Programmed current value. Units: 0.0. (as printed; see chapter 3: 0.01 A)
0x6aCurrent ramp rate. Units: mA/second.

Analog Current Mode Variables

Variable IDDescription
0x19Analog input scaling factor. Units: 0.01 A.
0x26Analog input dead band. Units: mV.
0x1aAnalog input offset. Units: mV.

PWM Current Mode Variables

Variable IDDescription
0xa9Digital input scaling factor. Units: 0.01 A.
0xa8Digital input command configuration.

Programmed Velocity Mode Variables

Variable IDDescription
0x2fProgrammed velocity command. Units: 0.1 counts/second.
0x36Velocity acceleration limit. Units: 1000 counts/second².
0x37Velocity deceleration limit. Units: 1000 counts/second².
0x39Fast stop ramp. Units: 1000 counts/second².

Analog Velocity Mode Variables

Variable IDDescription
0x19Analog input scaling factor. Units: 0.1 counts/second.
0x26Analog input dead band. Units: mV.
0x1aAnalog input offset. Units: mV.
0x36Velocity acceleration limit. Units: 1000 counts/second².
0x37Velocity deceleration limit. Units: 1000 counts/second².
0x39Fast stop ramp. Units: 1000 counts/second².

PWM Velocity Mode Variables

Variable IDDescription
0xa9Scaling Factor. Units: 0.1 counts/second.
0x36Velocity acceleration limit. Units: 1000 counts/second².
0x37Velocity deceleration limit. Units: 1000 counts/second².
0x39Fast stop ramp. Units: 1000 counts/second².
0xa8Digital input command configuration.

Programmed Position Mode Variables

Variable IDDescription
0xc8Profile type: 0 = Absolute move, trapezoidal profile; 1 = Absolute move, S-curve profile; 256 = Relative move, trapezoidal profile; 257 = Relative move, S-curve profile; 2 = Velocity profile.
0xcaPosition command: Relative move = the distance of the move; Absolute move = the target position of the move; Velocity move = 1 for positive direction, -1 for negative direction. Units: counts.
0xcbMaximum velocity. Units: 0.1 counts/second.
0xccMaximum acceleration rate. Units: 10 counts/second².
0xcdMaximum deceleration rate. Units: 10 counts/second².
0xceMaximum jerk rate. Units: 100 counts/second³.
0xcfAbort deceleration rate. Units: 10 counts/second².

Analog Position Mode Variables

Variable IDDescription
0x19Analog input scaling factor. Units: counts.
0x26Dead band. Units: mV.
0xcbMaximum velocity. Units: 0.1 counts/second.
0xccMaximum acceleration rate. Units: 10 counts/second².
0xcdMaximum deceleration rate. Units: 10 counts/second².
0xcfAbort deceleration rate. Units: 10 counts/second².

Pulse and Direction Mode Variables

Variable IDDescription
0xa8Digital Command Configuration. Pulse and Direction: 4096 = Increment position on rising edge; 0 = Increment position on falling edge. (as printed in Appendix A; chapter 3 gives the opposite assignment)
0xa9Scaling factor. Output counts/Input pulses.
0xcbMaximum velocity. Units: 0.1 counts/second.
0xccMaximum acceleration rate. Units: 10 counts/second².
0xcdMaximum deceleration rate. Units: 10 counts/second².
0xcfAbort deceleration rate. Units: 10 counts/second².

Pulse Up/Down Mode Variables

Variable IDDescription
0xa8Digital Command Configuration. Pulse Up/Down Mode: 4352 = Increment position on rising edge; 256 = Increment position on falling edge. (as printed in Appendix A; chapter 3 gives the opposite assignment)
0xa9Input / Output Ratio.
0xcbMaximum velocity. Units: 0.1 counts/second.
0xccMaximum acceleration rate. Units: 10 counts/second².
0xcdMaximum deceleration rate. Units: 10 counts/second².
0xcfAbort deceleration rate. Units: 10 counts/second².

Quadrature Mode Variables

Variable IDDescription
0xa8Digital Command Configuration. 512 = Quadrature Mode.
0xa9Input / Output Ratio.
0xcbMaximum velocity. Units: 0.1 counts/second.
0xccMaximum acceleration rate. Units: 10 counts/second².
0xcdMaximum deceleration rate. Units: 10 counts/second².
0xcfAbort deceleration rate. Units: 10 counts/second².

Homing Mode Variables

Variable IDDescription
0xc2Homing Method. See the homing methods table (chapter 3, Homing Mode) for values.
0xc3Fast Velocity. Units: counts/second.
0xc4Slow Velocity. Units: counts/second.
0xc5Acceleration / Deceleration. Units: 10 counts/second².
0xc6Home Offset. Units: counts.
0xc7Current Limit. Units: 0.01 A.
0xbfCurrent Delay Time. Units: milliseconds.
0xb8Positive Software Limit. Units: counts.
0xb9Negative Software Limit. Units: counts.

Current Loop Limits Variables

Variable IDDescription
0x21Peak current limit. Units: 0.01 A.
0x23I²T time limit. Units: mS.
0x22Continuous current limit. Units: 0.01 A.
0xaeCurrent loop offset. Units: 0.01 A.

Current Loop Gains Variables

Variable IDDescription
0x00Current loop proportional gain (Cp).
0x01Current loop integral gain (Ci).

Velocity Loop Limits Variables

Variable IDDescription
0x3aVelocity loop velocity limit. Units: 0.01 counts/second.
0x36Velocity loop acceleration limit. Units: 1000 counts/second².
0x37Velocity loop deceleration Limit. Units: 1000 counts/second².
0xcfFast Stop Ramp. Units: 10 counts/second².

Velocity Loop Gains Variables

Variable IDDescription
0x27Velocity loop proportional gain (Vp).
0x28Velocity loop integral gain (Vi).

Velocity Loop Filters Variables

Variable IDDescription
0x6bVelocity loop command filter co-efficients.
0x5fVelocity loop output filter co-efficients.

Position Loop Gains Variables

Variable IDDescription
0x30Pp - Position loop proportional gain.
0x33Vff - Velocity feed forward.
0x34Aff - Acceleration feed forward.
0xe3Position loop gain multiplier.

Current Loop Run Time Variables

Variable IDDescription
0x15Commanded current. Units: 0.01 A.
0x0cActual current. Units: 0.01 A.
0x25Limited current. Units: 0.01 A.

Velocity Loop Run Time Variables

Variable IDDescription
0x2cCommanded velocity. Units: 0.1 counts/second.
0xcbProfile velocity. Units: 0.1 counts/second.
0x29Limited velocity. Units: 0.1 counts/second.
0x18Motor velocity. Units: 0.1 counts/second.
0x5eLoad velocity. Units: 0.1 counts/second.
0x2aVelocity loop error.

Position Loop Run Time Variables

Variable IDDescription
0x3dCommanded position. Units: counts.
0x2dLimited position. Units: counts.
0x32Motor position. Units: counts.
0x17Load position. Units: counts.
0x35Following Error. Units: counts.

Position Loop Inputs from the Trajectory Generator (Variables)

Variable IDDescription
0x3bProfile velocity. Units: 0.1 counts/second.
0x3cProfile acceleration. Units: 10 counts/second².
0x2dLimited position. Units: counts.

Miscellaneous System Variables

Variable IDDescription
0x1dAnalog input voltage. Units: mV.
0x1bSin input voltage.
0x1cCos input voltage.
0x1eBus voltage. High voltage A/D reading. Units: 100 mV.
0x20Amplifier temperature. Units: degrees C.
0xb0Phase angle. Units: degrees.
0x90Baud rate.

Inputs and Outputs

Variable IDDescription
0xa6Read input states.
0xabRead/Write output states.
0x70 thru 0x77Configure outputs.

Status and State Variables

Variable IDDescription
0xa0Status Register.
0xc9Trajectory Register.
0xa4Fault Register.
0x24Amplifier desired state.

Słowa kluczowe

lista zmiennych, variable ID, quick reference, zmienne Copley, jednostki, 0x24, 0xa0, 0xc9, 0xa4, 0x32, 0x18, 0x0c, 0xa6, 0xab