11. FAQ (Frequently Asked Questions)
Streszczenie: Najczęstsze problemy z czytnikiem ID3000: ciemny obraz, niska liczba klatek w podglądzie, brak połączenia z klientem i brak obrazu w podglądzie na żywo – przyczyny i rozwiązania.
EN: ID3000 FAQ: dark image, low frame rate, client cannot connect to the device, and no image in live view – reasons and solutions.
Dotyczy: przemysłowy czytnik kodów Hikrobot serii ID3000 (złącze M12 17-pin, Fast Ethernet, RS-232; obsługa przez klienta IDMVS)
Źródło: dokumentacja producenta (Hikrobot ID3000 Series Industrial Code Reader User Manual, V3.1.0)
11.1 Why Is the imageImage isVery very dark?
Dark?
Problem
All black or too dark during preview.
Reason●
- Insufficient brightness of supplement light.
● - Too small adjustment value of exposure and gain.
● - The polarization lens cap may be used. The brightness of the polarization lens cap is low, and it is not recommended to use it in normal
condition.
conditions.
Solution●
- Increase the brightness of supplement light appropriately, or change to a brighter one.
- Increase exposure and gain appropriately.
● Increase exposure and gain appropriately.
11.2 Why Is the image'sImage Frame Rate Very Low in the Live View?
Problem
Image incoherent / low frame rate is/ very low in the live view?ProblemImage incoherent/Low frame rate/Imageimage tearing when adjusting the view preview.
Reason
Network circuitry speed is not 100 Mbps.
Solution
Check whether the network transittransmission speed is 100 Mbps or not.
11.3 Why Can’t the Client Software Connect to the Device?
This heading is missing in the source document and has been reconstructed from the reasons and solutions listed below.
Reason●
- The device is powered off.
● - Network exception.
Solution●
- Check the device power connection (observe whether the top PWR light is solid green or not), to make sure the device is powered up normally.
● - Check the network connection (observe whether the top LNK light is flashing green or not), to make sure the device can be connected to the network normally. The PC port and the device
aremust be in the same network segment.
11.4 Why thereIs isThere noNo imageImage in the liveLive view?
View?
Problem
No image in the live view.
Reason●
- Trigger
Enabledmodetriggerismode,enabled, but there is no trigger signal.● - Network circuitry speed is not 100 Mbps.
Solution● Sent
- Send the trigger signal to the
device/Disabledevice, or disable the trigger mode.● - Check whether network circuitry speed is 100 Mbps or not.
Słowa kluczowe
Hikrobot ID3000, FAQ, troubleshooting, dark image, exposure, gain, polarization lens cap, frame rate, 100 Mbps, PWR, LNK, trigger mode, no image, diagnostyka