11.1 Why Is the Image Very Dark?

Problem

All black or too dark during preview.

Reason

  • Insufficient brightness of supplement light.
  • Too small adjustment value of exposure and gain.
  • The polarization lens cap may be used. The brightness of the polarization lens cap is low, and it is not recommended to use it in normal conditions.

Solution

  • Increase the brightness of supplement light appropriately, or change to a brighter one.
  • Increase exposure and gain appropriately.

11.2 Why Is the Image Frame Rate Very Low in the Live View?

Problem

Image incoherent / low frame rate / image tearing when adjusting the view preview.

Reason

Network circuitry speed is not 100 Mbps.

Solution

Check whether the network transmission speed is 100 Mbps or not.

11.3 Why Can’t the Client Software Connect to the Device?

This heading is missing in the source document and has been reconstructed from the reasons and solutions listed below.

Reason

  • The device is powered off.
  • Network exception.

Solution

  • Check the device power connection (observe whether the top PWR light is solid green or not), to make sure the device is powered up normally.
  • Check the network connection (observe whether the top LNK light is flashing green or not), to make sure the device can be connected to the network normally. The PC port and the device must be in the same network segment.

11.4 Why Is There No Image in the Live View?

Problem

No image in the live view.

Reason

  • Trigger mode is enabled, but there is no trigger signal.
  • Network circuitry speed is not 100 Mbps.

Solution

  • Send the trigger signal to the device, or disable the trigger mode.
  • Check whether network circuitry speed is 100 Mbps or not.