7. Device Mode Settings

Streszczenie: Tryby pracy czytnika ID3000 (Test, Normal, Raw), wybór trybu w oknie podglądu na żywo oraz podgląd efektu odczytu kodów.
EN: ID3000 device modes (Test, Normal, Raw), selecting the mode in the live view window and previewing the code reading effect.

Dotyczy: przemysłowy czytnik kodów Hikrobot serii ID3000 (złącze M12 17-pin, Fast Ethernet, RS-232; obsługa przez klienta IDMVS)
Źródło: dokumentacja producenta (Hikrobot ID3000 Series Industrial Code Reader User Manual, V3.1.0); tabele i uwagi przepisane z obrazów na tekst, opisy rysunków – opracowanie Multiprojekt

Device Modes

The device supports 3 types of operating modes, including Test, Normal, and Raw. You can select different modes in live view window according to actual demands.

Note:

  • Stopping the real-time acquisition is required before selecting modes.
  • You need to set device mode as Normal before specific device settings. Otherwise, the device parameters may be different.

Device mode drop-down list: Normal, Test, Raw

Figure 7-1 Select Device Mode

Figure description (text version): Live view toolbar with the mode drop-down list expanded at the top left (Normal selected, Test, Raw), followed by acquisition, capture, recording and layout buttons.

Table 7-1 Device Mode Description

Device ModeDescription
Test ModeIt is used during device debugging. The device outputs images that are acquired in real-time, and displays code information.
Normal ModeIt is used during device normal operation. After reading code in image, the device outputs image and code information.
Raw ModeIt is used during testing image data. The device outputs raw data and displays code information.

Code Reading Preview

You can click Start acquisition icon in the live view window to view images and the code reading effect. If the effect is not very good, you can adjust the focus knob (the manual focus device only) or related parameters in Image Settings area.

Live view in Test mode with three DataMatrix codes framed

Figure 7-2 Code Reading

Figure description (text version): Live view window in Test mode: three DataMatrix codes on a part, each framed in a different colour (blue, red, yellow); the read results are listed in matching colours in the lower left corner and the status bar shows acquisition rate, image number, resolution and display rate.

Słowa kluczowe

Hikrobot ID3000, device mode, Test mode, Normal mode, Raw mode, tryb pracy, live view, code reading