Bootstrak Skip to main content

12. FAQ (Frequently Asked Questions)

Streszczenie: Najczęstsze problemy z czytnikiem ID2000: brak urządzenia na liście IDMVS, ciemny obraz, niska liczba klatek w podglądzie i brak obrazu – przyczyny i rozwiązania.
EN: ID2000 FAQ: no device listed in IDMVS, dark image, low frame rate in live view and no image – reasons and solutions.

Dotyczy: przemysłowy czytnik kodów Hikrobot serii ID2000 (typy I–VII; Fast Ethernet, USB lub RS-232; obsługa przez klienta IDMVS i kody konfiguracyjne)
Źródło: dokumentacja producenta (Hikrobot ID2000 Series Industrial Code Reader User Manual)

12.1 Why There Is No Device Listed After I Run the IDMVS Client Software?

Problem

Run IDMVS client, there is no listed device.

Reason

  • The device is powered off.
  • Network exception.

Solution

  • Check the device’s power connection (observe whether the PWR indicator is solid green) to make sure the device is powered up normally.
  • Check the network connection (the LNK indicator is flashing green if the network exception occurs) to make sure the device can be connected to the network normally, and make sure that the PC and the device are in the same network segment.

12.2 Why the Image Is Very Dark?

Problem

All black or too dark during live view.

Reason

  • Insufficient brightness of light source.
  • Too small value of exposure and gain.

Solution

  • Increase the brightness of light source appropriately, or change to a brighter one.
  • Increase exposure and gain appropriately.

12.3 Why the Image's Frame Rate Is Very Low in the Live View?

Problem

Image incoherent/low frame rate/image tearing when adjusting images.

Reason

Network circuitry speed is not 100 Mbps.

Solution

Check whether the network transit speed is 100 Mbps or not.

12.4 Why There Is No Image in the Live View?

Problem

No image in the live view.

Reason

  • Enabled trigger mode, but there is no trigger signal.
  • Network circuitry speed is not 100 Mbps.

Solution

  • Send the trigger signal to the device, or disable the trigger mode.
  • Check whether the network circuitry speed is 100 Mbps or not.

Słowa kluczowe

Hikrobot ID2000, FAQ, troubleshooting, no device listed, IDMVS, PWR, LNK, dark image, exposure, gain, frame rate, 100 Mbps, trigger mode, diagnostyka