Bootstrak Skip to main content

5. Installation

Streszczenie: Instalacja czytnika ID2000: akcesoria (kabel, zasilacz, śruby, IO box), uwagi dotyczące zasilania USB i zasilaczy impulsowych oraz kroki montażu i podłączenia dla poszczególnych typów (Fast Ethernet, USB, RS-232).
EN: ID2000 installation: accessories (cable, power supply, screws, IO box), cautions for USB power and industrial switching power supplies, and mounting/wiring steps for each type (fast Ethernet, USB, RS-232).

Dotyczy: przemysłowy czytnik kodów Hikrobot serii ID2000 (typy I–VII; Fast Ethernet, USB lub RS-232; obsługa przez klienta IDMVS i kody konfiguracyjne)
Źródło: dokumentacja producenta (Hikrobot ID2000 Series Industrial Code Reader User Manual); tabele i uwagi przepisane z obrazów na tekst – opracowanie Multiprojekt

5.1 Installation Preparation

You need to prepare following accessories before installation.

Table 5-1 Accessories

No.NameQuantityDescription
1Cable1It refers to the supplied cable that is included in the package. Refer to section Connector and Cable for details.
2Power Adapter or Switch Power Supply1You should select a suitable power adapter or switch power supply according to the device power supply and consumption. You need to purchase it separately.
3Screw PackageSeveralIt refers to the supplied screws that are used to fix the device to the installation position.
4IO Box1It is used to connect NPN/PNP devices.
Note: The IO box may not be included in the package due to different device models.

5.2 Install Device

Before You Start

  • Make sure that the device in the package is in good condition and all assembly parts are included.
  • Make sure that all related equipment is powered off during the installation.

Caution:

  • A device with USB data interface may have a risk if it uses USB 2.0 power supply of 500 mA; it is recommended to use USB 3.0 power supply.
  • Some models of the device’s supplied cable have a power open line, which has the same function as the DB9 connector to power the device. Do not use them at the same time. Otherwise, the power supply may be damaged.
  • When using an industrial switching power supply, pay attention to the following:
    • Before executing any installation or maintenance work, ensure that the power supply is separated from the main electric supply, and that it will not suddenly be reconnected or have wiring problems with the main electric supply.
    • Do not install the power supply in a humid environment, near liquids, in a high-temperature environment, in direct sunlight or near fire sources.
    • The industrial switching power supply has exposed high-voltage terminals; install it in a closed chassis or cabinet to prevent accidental contact with personnel.
    • The internal components of the power supply should maintain sufficient insulation distance between the mounting screws.
    • The fan and the cooling holes must not be covered. If the adjacent equipment is a heat source, keep a distance of at least 10 cm to 15 cm from it.
    • Ensure that the power supply is grounded as required before use.
    • When using the power supply, do not exceed the upper limit of its output current and power. Refer to the power supply nameplate parameters for details.
    • Non-standard installation or use of the power supply in a high-temperature environment will increase the temperature of internal components, resulting in a decrease in output power.
    • The power supply contains a high-voltage dangerous circuit. If there is any abnormality, cut off the power first and hand it over to a technician with electrical professional qualification. Do not open the outer cover by yourself.
    • Do not touch the power terminal within 5 minutes after the power is cut off. Otherwise, it may cause electric shock.

Steps

  1. Use supplied screws to fix the device to the installation position.
  2. Use the supplied cable to wire the device according to pin definition mentioned in section Connector and Cable.
    • For type I to type V devices with fast Ethernet interface, connect the 17-pin M12 connector of the cable to the device, insert RJ45 connector of the cable into a switch or a PC for debugging images or transmitting data, and connect DB9 connector to a proper power adapter for power supply.
    • For type VI device with fast Ethernet interface, connect the DB15 connector of the cable to the device, insert RJ45 connector of the cable into a switch or a PC for debugging images or transmitting data, and connect DB9 connector to a proper power adapter for power supply.
    • For type I to type V devices with USB Interface, connect the 17-pin M12 connector of the cable to the device, and connect the USB interface of the cable to the PC.
    • For type VI device with USB interface, connect the device to the supplied cable via the DB15 connector, and connect the USB interface of the cable to the PC.
    • For type VII device with USB interface, insert RJ45 male connector of the cable into the device, and connect USB interface to external devices.
    • For type VII device with RS-232 interface, insert RJ45 male connector of the cable into the device, and connect RS-232 interface to external devices.

Słowa kluczowe